Additional information
| Weight | 310 g |
|---|---|
| Dimensions | 7.7 × 4.5 × 8.6 cm |
| Extended Product Type | AF09-30-10-14 |
| Standard | CSA C22.2 No. 60335-2-40 LZGH2 A2L, CSA C22.2 No. 60947-4-1, IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60335-2-40 LZGH2 A2L, UL 60947-4-1 |
| Number of Poles | 3P |
| Rated Current | 35A |
| Rated Voltage | 690V |
| Rated Power | 4kW |
| Rated Frequency | 50/60Hz |
| Breaking Capacity | 100A |
| Frame size | 00 |
| Mounting | TH35-15 (35 x 1.5 cm Mounting Rail) acc. to IEC 60715 |
| Degree of Protection IP | IP20 |
| Mounting Type | TH35-15 (35 x 1.5 cm Mounting Rail) acc. to IEC 60715 |
| Rated Cross-Section | 0.75…6 mm² |
| Terminal Type | Screw Terminals |
| Product Net Depth (MM) | 7.7 cm |
| Customs Tariff Number | 85364900 |
| Minimum Order Quantity | 1 |
| Temperature Range | -25…60°C |
| GTIN (EAN) | 3.47152E+12 |
| Resistance | 4 g Closed Position & 2 g Open position 5 … 300 Hz |
| L1 | |
| L2 | Switchgear & Contactors |
| L3 | Contactors |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| Climatic Withstand | Category B according to IEC 60947-1 Annex Q |
| Connecting Capacity Auxiliary Circuit | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² |
| Connecting Capacity Auxiliary Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Connecting Capacity Control Circuit | Flexible with Ferrule 1/2x 0.75 … 2.5 mm² |
| Connecting Capacity Control Circuit UL/CSA | Rigid Solid 1/2x 18-14 AWG |
| Connecting Capacity Main Circuit UL/CSA | Rigid Solid 1/2x 16-10 AWG |
| Country of Origin | Switzerland |
| Full Load Amps Motor Use | (120 V AC) Single Phase 13.8 A |
| General Use Rating UL/CSA | (600 V AC) 25 A |
| Horsepower Rating NEMA | (115 V AC) Single Phase 1/3 Hp |
| Horsepower Rating UL/CSA | (120 V AC) Single Phase 3/4 hp |
| Improved Energy Efficiency for Customers | Product Efficiency – Product considered more energy-efficient compared to similar product on market or older products from the same line |
| Maximum Electrical Switching Frequency | (AC-1) 600 cycles per hour |
| Maximum Mechanical Switching Frequency | 3600 cycles per hour |
| Maximum Operating Altitude Permissible | Without Derating 3000 m |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V |
| Mounting by Screws (not supplied) | 2 x M4 Screws Placed Diagonally |
| Number of Auxiliary Contacts NC | 0 |
| Number of Auxiliary Contacts NO | 1 |
| Number of Main Contacts NC | 0 |
| Number of Main Contacts NO | 3 |
| Operate Time | Between Coil De-energization and NC Contact Closing 13 … 98 ms |
| Package Level 1 Depth / Length | 7.9 cm |
| Package Level 1 Gross Weight | 310 g |
| Package Level 1 Height | 4.7 cm |
| Package Level 1 Width | 8.7 cm |
| Pollution Degree | 3 |
| Power Loss | at 6 A per Pole 0.1 W |
| Product Name | Block Contactor |
| Rated Control Circuit Voltage (Uc) | 50 Hz 250 … 500 V |
| Rated Impulse Withstand Voltage (Uimp) | 6 kV |
| Rated Insulation Voltage (Ui) | acc. to IEC 60947-4-1 690 V |
| Rated Operational Current AC-15 (Ie) | (500 V) 2 A |
| Rated Operational Current AC-3e (Ie) | (415 V) 60 °C 9 A |
| Rated Operational Current DC-1 (Ie) | (110 V) 1-Pole, 40 °C 10 A |
| Rated Operational Current DC-13 (Ie) | (24 V) 6 A / 144 W |
| Rated Operational Current DC-3 (Ie) | (110 V) 1-Pole, 40 °C 6 A |
| Rated Operational Current DC-5 (Ie) | (110 V) 1-Pole, 40 °C 4 A |
| Rated Short-time Withstand Current Low Voltage (Icw) | at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 A |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops – Standard EN45555 – 92.7 % |
| Tightening Torque | Auxiliary Circuit 1.2 N·m |
| Tightening Torque UL/CSA | Auxiliary Circuit 11 in·lb |
| Wire Stripping Length | Auxiliary Circuit 1 cm |