ABB

MS132-12 MM-Starter ( 8.0…12.0 A)

$13.00

MS132-12 Manual Motor Starter 8.0 … 12 A

In Stock

Bulk Pricing

QuantityPrice
1 - 5 $13.00
6 - 10 $12.74
11 - 50 $12.48
51 - 200 $12.22
200+ $11.96

In stock

  • ✅ Free global shipping on all orders
  • ✅ 30 days easy returns if you change your mind
  • ✅ Order before noon for same day dispatch
Guaranteed Safe Checkout

Additional information

Weight310 g
Extended Product Type

MS132-12

Standard

IEC/EN 60947-1

Number of Poles

3P

Rated Current

12A

Rated Voltage

690VAC

Rated Power

5.5kW

Rated Frequency

50Hz

Breaking Capacity

100kA

Mounting

1 … 6

Row Spacing

Electrical Conductive Board, Horizontal – Up to 400 V 0 mm

Degree of Protection IP

IP20

Tripping Characteristic

1SAM300505F0012

Mounting Type

TH35-15 (35 x 1.5 cm Mounting Rail) acc. to IEC 60715

Rated Cross-Section

0.75…6 mm²

Setting range

8.0…12A

Terminal type

Screw Terminals

Product Net Depth (MM)

8.655 cm

Customs Tariff Number

85362010

Minimum Order Quantity

1

Temperature Range

0…+40°C

GTIN (EAN)

4.01361E+12

Status indicator

ON / OFF / TRIP

resistance

5 g 3 … 150 Hz

L1

Electrical

L2

Switchgear & Contactors

L3

Motor Starters (DOL / Star-Delta)

ABB EcoSolutions

Yes

ABB Site Meeting Group Waste To Landfill Target

No non-hazardous waste is sent to a landfill

Actuator Type

Rotary Handle

Ambient Air Temperature Compensation

Yes

Connecting Capacity Main Circuit UL/CSA

Flexible 1/2x 16-8 AWG

Country of Origin

Germany

Criticality

No

Electrical Durability

50000 cycle

Full Load Amps Motor Use

(200 V AC) Three Phase 11 A

General Use Rating UL/CSA

(600 V AC) 12 A

Horsepower Rating UL/CSA

(200 V AC) Three Phase 3 Hp

Locked Rotor Amps

(200 V AC) Three Phase 73.6 A

Maximum Operating Altitude Permissible

2000 m

Maximum Operating Voltage UL/CSA

Main Circuit 600 V AC

Mechanical Durability

Nr. Operations 100000 cycle

Note

No

Package Level 1 Depth / Length

10.2 cm

Package Level 1 Gross Weight

325 g

Package Level 1 Height

5 cm

Package Level 1 Width

9.2 cm

Package Level 2 Depth / Length

39.5 cm

Package Level 2 Gross Weight

13.386 kg

Package Level 2 Height

21 cm

Package Level 2 Units

carton 40 piece

Package Level 2 Width

28 cm

Pollution Degree

3

Power Loss

at Rated Operating Conditions per Pole 1.0 … 2.3 W

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 6 kV

Rated Instantaneous Short-Circuit Current Setting (Ii)

180 A

Rated Insulation Voltage (Ui)

690 V

Rated Operational Current AC-3e (Ie)

12:00 AM

Rated Operational Current DC-5 (Ie)

12:00 AM

Recyclability Rate of the Product acc. to EN45555

Design for Closing Resource Loops – Standard EN45555 – 80 %

Remarks

UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx

Technical Information

MOTOR PROTECTION SWITCH

Tightening Torque

Main Circuit 2 N·m

Tightening Torque UL/CSA

Main Circuit 18 in·lb

Wire Stripping Length

Main Circuit 1 cm