Additional information
| Weight | 215 g |
|---|---|
| Extended Product Type | MS132-0.16 |
| Standard | IEC/EN 60947-1 |
| Number of Poles | 3P |
| Rated Current | 0.16A |
| Rated Voltage | 690VAC |
| Rated Power | 0.03kW |
| Rated Frequency | 50Hz |
| Breaking Capacity | 100kA |
| Mounting | 1 … 6 |
| Row Spacing | Electrical Conductive Board, Horizontal – Up to 400 V 0 mm |
| Degree of Protection IP | IP20 |
| Tripping Characteristic | 1SAM300505F0101 |
| Mounting Type | TH35-15 (35 x 1.5 cm Mounting Rail) acc. to IEC 60715 |
| Rated Cross-Section | 0.75…2.5 mm² |
| Setting range | 0.10…0.16A |
| Terminal type | Screw Terminals |
| Product Net Depth (MM) | 8.675 cm |
| Customs Tariff Number | 85362010 |
| Minimum Order Quantity | 1 |
| Temperature Range | 0…+40°C |
| GTIN (EAN) | 4.01361E+12 |
| Status indicator | ON / OFF / TRIP |
| resistance | 5 g 3 … 150 Hz |
| L1 | Electrical |
| L2 | Switchgear & Contactors |
| L3 | Motor Starters (DOL / Star-Delta) |
| ABB EcoSolutions | Yes |
| ABB Site Meeting Group Waste To Landfill Target | No non-hazardous waste is sent to a landfill |
| Actuator Type | Rotary Handle |
| Ambient Air Temperature Compensation | Yes |
| Connecting Capacity Main Circuit UL/CSA | Flexible 1/2x 16-12 AWG |
| Electrical Durability | 50000 cycle |
| Full Load Amps Motor Use | (200 V AC) Three Phase 0.16 A |
| General Use Rating UL/CSA | (600 V AC) 0.16 A |
| Locked Rotor Amps | (200 V AC) Three Phase 0.96 A |
| Maximum Operating Altitude Permissible | 2000 m |
| Maximum Operating Voltage UL/CSA | Main Circuit 600 V AC |
| Mechanical Durability | Nr. Operations 100000 cycle |
| Package Level 1 Depth / Length | 9.5 cm |
| Package Level 1 Gross Weight | 230 g |
| Package Level 1 Height | 5 cm |
| Package Level 1 Width | 9.2 cm |
| Package Level 2 Depth / Length | 39.5 cm |
| Package Level 2 Gross Weight | 9.586 kg |
| Package Level 2 Height | 21 cm |
| Package Level 2 Units | carton 40 piece |
| Package Level 2 Width | 28 cm |
| Pollution Degree | 3 |
| Power Loss | at Rated Operating Conditions per Pole 0.7 … 1.7 W |
| Rated Impulse Withstand Voltage (Uimp) | Main Circuit 6 kV |
| Rated Instantaneous Short-Circuit Current Setting (Ii) | 2:00 AM |
| Rated Insulation Voltage (Ui) | 690 V |
| Rated Operational Current AC-3e (Ie) | 0.16 A |
| Rated Operational Current DC-5 (Ie) | 0.16 A |
| Recommended Screw Driver | Pozidriv 2 |
| Recyclability Rate of the Product acc. to EN45555 | Design for Closing Resource Loops – Standard EN45555 – 80 % |
| Remarks | UL508 Self-Protected Combination Motor Controller (Type E) in combination with feeder block S1-M3-xx |
| Tightening Torque | Main Circuit 0.8 … 1.2 N·m |
| Tightening Torque UL/CSA | Main Circuit 10 … 12 in·lb |
| Wire Stripping Length | Main Circuit 9 mm |