ABB

eOVR T1-T2 3N 12.5-440s

eOVR T1-T2 3N 12.5-440s Digital SPD for energy management via Modbus RTU SPD T1+2, 400/690V TT/TNS system

On Order

Bulk Pricing

QuantityPrice
1 - 5 $0.00
6 - 10 $0.00
11 - 50 $0.00
51 - 200 $0.00
200+ $0.00
SKU: 2TAM913100R5811 Category: Tags: , , Brands:
  • ✅ Free global shipping on all orders
  • ✅ 30 days easy returns if you change your mind
  • ✅ Order before noon for same day dispatch
Guaranteed Safe Checkout

Description

Digital SPDs from the eOVR series offer protection against transient overvoltages and tested in accordance with IEC 61643-11. By connecting via RTU Modbus, various types of device information can be obtained and visualized on a dashboard via ABB’s InSite energy management system web server. This level of connectivity enables real-time remote monitoring, predictive maintenance and increases the level of protection of the electrical installation against transient overvoltages.

Additional information

Weight1.16 kg
Dimensions7.67 × 15.19 × 13 cm
Extended Product Type

eOVR T1-T2 3N 12.5-440s

Standard

IEC 61643-11 / GB/T 18802.1 / NB/T 10284 / EN 61000-6-2/EN 61000-6-3

Number of Poles

3P+N

Execution Type

Plug-in

Rated Voltage

400VAC

Breaking Capacity

100KA

Mounting

DIN-Rail

Application

To protect the systems against the transient overvoltage (lightning)

Fuse system

4 modular spacing

Degree of Protection IP

IP20

Mounting Type

DIN-Rail

Communication

Modbus

Product Net Depth (MM)

7.67 cm

Minimum Order Quantity

1

DIN Place Units

8.5

GTIN (EAN)

6.94159E+12

Status indicator

Yes

Surge protection

2 kV

L1

L2

Switchgear & Contactors

L3

Disconnect Switches

ABB EcoSolutions

Yes

ABB Site Meeting Group Waste To Landfill Target

No non-hazardous waste is sent to a landfill

Cross-Section (<span style=\

Maximum Conductor Solid-Stranded 2.5 cm²

Discharge Current

Nominal 20 kA

Extended Product Lifetime

Product Durability

Improved Energy Efficiency for Customers

Process Efficiency – Product improves/optimizes process

Lightning Impulse Current

12.5 kA

Maximum Continuous Operating Voltage (Uc)

(L-PE) 440 V

Maximum Operating Altitude Permissible

Without Derating 2000 m

Nominal AC Voltage of the System (Uo)

400 /600 V

Options Provided

Monitoring :\nSurge event counter\nSPD end of life prediction\nUpstream back up status\nSPD status\nAmbient temperature\nNominal voltage\nSurge amplitude\nSurge time\n\nAlarm :\nFront face blinking LED\nLeakage current\nOvervoltage\nUndervoltage\nUpstream back up status\nMOV end of life treshold\nSPD status

Package Level 1 Gross Weight

1.256 kg

Position of Neutral Terminals

Right

Preventive Maintenance Feature

No

Recyclability Rate of the Product acc. to EN45555

Design for Closing Resource Loops – Standard EN45555 – 45.1 %

Temporary Overvoltage Test Value (UT)

(L-N) 337 V

Type of Low Voltage Distribution System

TT