ABB

AX32-30-01-80 220-230V50Hz/230-240V60Hz Contactor

$23.69

AX32-30-01-80 220-230V50Hz/230-240V60Hz Contactor

In Stock

Bulk Pricing

QuantityPrice
1 - 5 $23.69
6 - 10 $23.22
11 - 50 $22.74
51 - 200 $22.27
200+ $21.79

In stock

SKU: 1SBL281074R8001 Category: Tags: , , Brands:
  • ✅ Free global shipping on all orders
  • ✅ 30 days easy returns if you change your mind
  • ✅ Order before noon for same day dispatch
Guaranteed Safe Checkout

Description

AX32, AX40 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC. These contactors are of the block type design with: – 3 main poles and 1 built-in auxiliary contact – control circuit: AC operated – add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

Additional information

Weight667 g
Dimensions9 × 5.4 × 10.83 cm
Extended Product Type

AX32-30-01-80

Rated Current

65A

Rated Voltage

690V

Rated Power

15kW

Rated Frequency

50/60Hz

Breaking Capacity

100A

Degree of Protection IP

IP20

Terminal Type

Screw Terminals

Product Net Depth (MM)

9 cm

Customs Tariff Number

85364900

Minimum Order Quantity

1

Temperature Range

-25…55°C

GTIN (EAN)

3.47152E+12

L1

L2

Switchgear & Contactors

L3

Contactors

Climatic Withstand

according to IEC 60068-2-30 and 60068-2-11 – UTE C 63-100 Specification II

Full Load Amps Motor Use

(120 V AC) Single Phase 34 A

General Use Rating UL/CSA

(600 V AC) 50 A

Horsepower Rating UL/CSA

(120 V AC) Single Phase 3 hp

Maximum Electrical Switching Frequency

(AC-1) 600 cycles per hour

Maximum Mechanical Switching Frequency

3600 cycles per hour

Maximum Operating Altitude Permissible

Without Derating 3000 m

Number of Auxiliary Contacts NC

1

Number of Auxiliary Contacts NO

0

Number of Main Contacts NC

0

Number of Main Contacts NO

3

Operate Time

Between Coil De-energization and NC Contact Closing 7 … 14 ms

Package Level 1 Depth / Length

10.1 cm

Package Level 1 Gross Weight

710 g

Package Level 1 Height

11.5 cm

Package Level 1 Width

6.5 cm

Power Loss

at Rated Operating Conditions AC-1 per Pole 2.5 W

Product Name

Block Contactor

Rated Control Circuit Voltage (Uc)

50 Hz 220 … 230 V

Rated Impulse Withstand Voltage (Uimp)

Auxiliary Circuit 6 kV

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 690 V

Rated Operational Current AC-15 (Ie)

(500 V) NC 2

Rated Operational Current DC-13 (Ie)

(24 V) 6 A / 144 W

Rated Short-time Withstand Current Low Voltage (Icw)

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 400 A

Tightening Torque

Auxiliary Circuit 1 N·m

Tightening Torque UL/CSA

Auxiliary Circuit 9 in·lb