ABB

MS132-2.5T

MS132-2.5T Circuit Breaker for Primary Transformer Protection 1.6 … 2.5 A

On Order

Bulk Pricing

QuantityPrice
1 - 5 AED0.00
6 - 10 AED0.00
11 - 50 AED0.00
51 - 200 AED0.00
200+ AED0.00
SKU: 1SAM340000R1007 Category: Tags: , , Brands:
  • ✅ Free global shipping on all orders
  • ✅ 30 days easy returns if you change your mind
  • ✅ Order before noon for same day dispatch
Guaranteed Safe Checkout

Additional information

Weight265 g
Extended Product Type

MS132-2.5T

Standard

IEC/EN 60947-1

Number of Poles

3P

Rated Current

2.5A

Rated Voltage

690VAC

Rated Frequency

50Hz

Breaking Capacity

100kA

Mounting

1 … 6

Row Spacing

Electrical Conductive Board, Vertical 7.5 cm

Degree of Protection IP

IP20

Tripping Characteristic

1SAM300535F0007

Mounting Type

TH35-15 (35 x 1.5 cm Mounting Rail) acc. to IEC 60715

Rated Cross-Section

0.75…2.5 mm²

Setting range

1.6…2.5A

Terminal type

Screw Terminals

Product Net Depth (MM)

8.675 cm

Customs Tariff Number

85362010

Minimum Order Quantity

1

Temperature Range

0…+40°C

GTIN (EAN)

4.01361E+12

Status indicator

ON / OFF / TRIP

resistance

5 g 3 … 150 Hz

L1

Electrical

L2

Power Distribution

L3

Fuses & Fuse Holders

ABB EcoSolutions

Yes

ABB Site Meeting Group Waste To Landfill Target

No non-hazardous waste is sent to a landfill

Actuator Type

Rotary Handle

Ambient Air Temperature Compensation

Yes

Connecting Capacity Main Circuit UL/CSA

Flexible 1/2x 16-12 AWG

Country of Origin

Germany

Criticality

No

Electrical Durability

50000 cycle

Full Load Amps Motor Use

(120 V AC) Single Phase 2.5 A

Horsepower Rating UL/CSA

(220 … 240 V AC) Single Phase 0.17 Hp

Locked Rotor Amps

(120 V AC) Single Phase 15 A

Maximum Operating Altitude Permissible

2000 m

Maximum Operating Voltage UL/CSA

Main Circuit 600 V AC

Mechanical Durability

Nr. Operations 100000 cycle

Note

No

Package Level 1 Depth / Length

9.5 cm

Package Level 1 Gross Weight

280 g

Package Level 1 Height

5 cm

Package Level 1 Width

9.2 cm

Package Level 2 Depth / Length

39.5 cm

Package Level 2 Gross Weight

11.586 kg

Package Level 2 Height

21 cm

Package Level 2 Units

carton 40 piece

Package Level 2 Width

28 cm

Pollution Degree

3

Power Loss

at Rated Operating Conditions per Pole 0.6 … 1.6 W

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 6 kV

Rated Instantaneous Short-Circuit Current Setting (Ii)

50 A

Rated Insulation Voltage (Ui)

690 V

Recyclability Rate of the Product acc. to EN45555

Design for Closing Resource Loops – Standard EN45555 – 80 %

Tightening Torque

Main Circuit 0.8 … 1.2 N·m

Tightening Torque UL/CSA

Main Circuit 10 … 12 in·lb

Wire Stripping Length

Main Circuit 9 mm